Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 104: 1374-1380, 2008. First published February 28, 2008; doi:10.1152/japplphysiol.00825.2007
8750-7587/08 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
104/5/1374    most recent
00825.2007v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Young, C. N.
Right arrow Articles by Edwards, D. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Young, C. N.
Right arrow Articles by Edwards, D. G.

Ultrasound assessment of popliteal vein compliance during a short deflation protocol

Colin N. Young,1 Raju Y. Prasad,1 Adam M. Fullenkamp,1 Michael E. Stillbower,1,2 William B. Farquhar,1,2 and David G. Edwards1,2

1Department of Health, Nutrition, and Exercise Sciences, University of Delaware, Newark, Delaware; and 2Cardiovascular Research, Christiana Care Health System, Newark, Delaware

Submitted 1 August 2007 ; accepted in final form 26 February 2008

The purpose of the present study was to determine whether ultrasound is a useful tool to measure the venous characteristics of the lower extremity during a standard venous collecting cuff deflation protocol. To accomplish this, lower extremity pressure-cross-sectional area (CSA) and pressure-volume relationships were measured in eight (25 ± 1 yr) supine subjects. Popliteal vein CSA was assessed by using high-resolution ultrasound, while calf volume changes were simultaneously assessed by using venous occlusion plethysmography (VOP). Pressure-CSA and pressure-volume relationships were assessed at baseline, during the cold pressor (CP) test, and following sublingual nitroglycerin (NTG) administration. Relationships were modeled with a quadratic regression equation, and β1 and β2 were used as indexes of venous compliance. Popliteal vein regression parameters β1 (8.485 ± 2.616 vs. 7.638 ± 2.664, baseline vs. CP; 8.485 ± 2.616 vs. 7.734 ± 3.076, baseline vs. NTG; both P > 0.05) and β2 (–0.0841 ± 0.0241 vs. –0.0793 ± 0.0242, baseline vs. CP; –0.0841 ± 0.0241 vs. –0.0771 ± 0.0280, baseline vs. NTG; both P > 0.05) were not affected by CP or NTG. Similarly, calf regression parameters β1 and β2, obtained with VOP, were not altered during either trial. Intraclass correlations for venous compliance assessed with ultrasound and VOP were 0.92 and 0.97, respectively, indicating acceptable reproducibility. These data suggest that ultrasound is a functional and reproducible tool to assess the venous characteristics of the lower extremity, in addition to VOP. Additionally, popliteal vein and calf compliance were not affected by the CP test or NTG.

capacitance; cold pressor



Address for reprint requests and other correspondence: D. G. Edwards, 541 South College Ave., 142 Human Performance Laboratory, Newark, DE 19716 (e-mail: dge{at}udel.edu)




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
E. P. Delaney, C. N. Young, A. DiSabatino, M. E. Stillabower, and W. B. Farquhar
Limb venous tone and responsiveness in hypertensive humans
J Appl Physiol, September 1, 2008; 105(3): 894 - 901.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2008 by the American Physiological Society.